In the past few years, our business absorbed and digested advanced technologies both equally at home and abroad. In the meantime, our company staffs a group of experts devoted to your advancement of Insulated Rod, High Voltage Switchgear, 36kv Vacuum Circuit Breaker, Within our initiatives, we already have many shops in China and our solutions have won praise from prospects around the globe. Welcome new and outdated consumers to call us for that upcoming long term small business associations.
Air Load Break Switch Manufacturers – FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric Detail:

General

FN12-12D/630-20 indoor AC high voltage load switch(Hereinafter clled FNI2-12D load switch is is suitable for three-phase AC distribution system with rated voltage of 12 KV and rated frequency of 5OHz. It is used for opening and closing load current, closed loop current, no-loa transformer and cable charging current, closing short circuit current. The load switch equipped with the earthing switch can withstand the shor circuit current.

FNI2-12IR)D/25-31.5 indoor AC high voltage load switch–fuse combination (hereinafter called FN12-12IRJD combination) is an indoor high voltage switch device which combines FNI2-12D load switch and S□LAJ-12(XRNT□-10)high voltage current limiting fuse. It can break reliably under any current except it is up to short-circuit current. The load switch breaks the working current and the fuse breaks the short circuit current. And the combination breaks any overcurrent between the working current and the full short circuit current, and the fuse breal the load switch through its impactor.

Working Condition

●Ambient air temperature:Max.+40℃;Min.-25℃(Allowed to storage and transportation at-30℃) the average value is not higher than 35℃ with in 24 hours.
●Air relative humidity:Daily average is not greater than 95%, monthly average is not greater than 90% Earthquake intensity: no more than 8 degrees.
●Altitude:not more than 1000m
●No frequent and severe vibration Pollution level:ll
●The surrounding air is not contaminated by corrosive and flammab gases, water vapor, etc.

Technical specification

No.

Ltem

Unit

Data

FN12-12D/630

FN12-12(R)D/630

1

Rated voltage

KV

12

2

Rated frequency

Hz

50

3

Rated current

A

630 XX)

4

Lightning impulse withstand voltage

KV

To earth and phase Io phase75isolating frodure 85

5

1 min power frequency wtthsiand volloge

KV

To earth and phase to phase 42isolaling fracture 48

6

Rated fhermd stability current

KA

20(4S)

7

Rated dynamk current

KA

50

8

Rated dosing current (peak!

KA

50 50

50

9

Rated short drcuif breaking current (Expected value)

KA

31.5

10

Maximum at critical breaking current

A2S

Accorcing to the fuse characteristic curve

11

Minimum breaking currenf

KA

Accorcing to the fuse characteristic curve

12

Rated transfer current

KA

15

13

Maximum breaking current (reference valuel

KA

18

14

Breaking the capacity of the no-kx)d transformer

KVA

1250

15

Raled cable charging current

A

10

16

Raled active tood cunenl breaking limes

Times

> 100

17

The impodor touches lhe load switch opening time

S

0.06

> 0.06

18

Earthing switch Ihermal stabifcty current

KA

20(2S)

19

Earthing switch Ihermal stability current (peak)

KA

50

20

Motor operating power supply voboge

V

AC DC 110220

 Outline overall and installing dimensions

 FKRN12-12D Indoor High Voltage Gas Pressure Load Switch 001


Product detail pictures:

Air Load Break Switch Manufacturers –  FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric detail pictures

Air Load Break Switch Manufacturers –  FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric detail pictures

Air Load Break Switch Manufacturers –  FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric detail pictures


Related Product Guide:

Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for Air Load Break Switch Manufacturers – FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric , The product will supply to all over the world, such as: Vancouver, Buenos Aires, Surabaya, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world
  • It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Ellen from Las Vegas - 2017.04.18 16:45
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Matthew from Chile - 2018.02.08 16:45
    Write your message here and send it to us