With our leading technology as well as our spirit of innovation,mutual cooperation, benefits and development, we will build a prosperous future together with your esteemed company for 36kv Indoor Vacuum Circuit Breaker, Electr Switchgear, Aluminum Alloy Heater, We are able to do your tailored get to fulfill your own satisfactory! Our organization sets up several departments, including manufacturing department, sales department, high quality control department and sevice center, etc.
High Voltage Load Switch Suppliers – FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric Detail:

General

FN12-12D/630-20 indoor AC high voltage load switch(Hereinafter clled FNI2-12D load switch is is suitable for three-phase AC distribution system with rated voltage of 12 KV and rated frequency of 5OHz. It is used for opening and closing load current, closed loop current, no-loa transformer and cable charging current, closing short circuit current. The load switch equipped with the earthing switch can withstand the shor circuit current.

FNI2-12IR)D/25-31.5 indoor AC high voltage load switch–fuse combination (hereinafter called FN12-12IRJD combination) is an indoor high voltage switch device which combines FNI2-12D load switch and S□LAJ-12(XRNT□-10)high voltage current limiting fuse. It can break reliably under any current except it is up to short-circuit current. The load switch breaks the working current and the fuse breaks the short circuit current. And the combination breaks any overcurrent between the working current and the full short circuit current, and the fuse breal the load switch through its impactor.

Working Condition

●Ambient air temperature:Max.+40℃;Min.-25℃(Allowed to storage and transportation at-30℃) the average value is not higher than 35℃ with in 24 hours.
●Air relative humidity:Daily average is not greater than 95%, monthly average is not greater than 90% Earthquake intensity: no more than 8 degrees.
●Altitude:not more than 1000m
●No frequent and severe vibration Pollution level:ll
●The surrounding air is not contaminated by corrosive and flammab gases, water vapor, etc.

Technical specification

No.

Ltem

Unit

Data

FN12-12D/630

FN12-12(R)D/630

1

Rated voltage

KV

12

2

Rated frequency

Hz

50

3

Rated current

A

630 XX)

4

Lightning impulse withstand voltage

KV

To earth and phase Io phase75isolating frodure 85

5

1 min power frequency wtthsiand volloge

KV

To earth and phase to phase 42isolaling fracture 48

6

Rated fhermd stability current

KA

20(4S)

7

Rated dynamk current

KA

50

8

Rated dosing current (peak!

KA

50 50

50

9

Rated short drcuif breaking current (Expected value)

KA

31.5

10

Maximum at critical breaking current

A2S

Accorcing to the fuse characteristic curve

11

Minimum breaking currenf

KA

Accorcing to the fuse characteristic curve

12

Rated transfer current

KA

15

13

Maximum breaking current (reference valuel

KA

18

14

Breaking the capacity of the no-kx)d transformer

KVA

1250

15

Raled cable charging current

A

10

16

Raled active tood cunenl breaking limes

Times

> 100

17

The impodor touches lhe load switch opening time

S

0.06

> 0.06

18

Earthing switch Ihermal stabifcty current

KA

20(2S)

19

Earthing switch Ihermal stability current (peak)

KA

50

20

Motor operating power supply voboge

V

AC DC 110220

 Outline overall and installing dimensions

 FKRN12-12D Indoor High Voltage Gas Pressure Load Switch 001


Product detail pictures:

High Voltage Load Switch Suppliers –  FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric detail pictures

High Voltage Load Switch Suppliers –  FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric detail pictures

High Voltage Load Switch Suppliers –  FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric detail pictures


Related Product Guide:

"Control the standard by the details, show the power by quality". Our firm has strived to establish a extremely efficient and stable employees crew and explored an effective excellent command method for High Voltage Load Switch Suppliers – FKN12-12/FKRN12-12D Indoor High Voltage Gas Pressure Load Switch – Timetric , The product will supply to all over the world, such as: Ottawa, Chile, Albania, Adhering to the management tenet of "Managing Sincerely, Winning by Quality", we try our best to provide excellent products and service to our clients. We look forward to making progress together with domestic and international clients.
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Jean Ascher from Dominica - 2017.12.09 14:01
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Austin Helman from Jakarta - 2018.06.19 10:42
    Write your message here and send it to us